Heat recovery installation for data centers

In brief

Exporting waste heat to district heating is a process in its own right: heat exchange, temperature lift, control, pumping and metering. Finkova delivers the valves, pumps and metering for heat recovery and installs them together with the recovery piping and instrumentation. Our energy-sector background makes it familiar ground.

Delivery scope

  • Valves, pumps and metering for the heat recovery loop and the district heating connection.
  • Installation of heat recovery piping, valves, pumps and instrumentation.
  • Commissioning support for the interfaces between cooling, heat recovery and the district heating connection, including the bypass.
  • Measurement verification, handover documentation and maintenance planning.

Responsibilities and interfaces

The cooling system, the heat recovery plant and the district heating network have separate operating requirements. Their interfaces, bypass arrangements and test responsibilities are agreed with the owner, the equipment suppliers and the network operator. Contractual heat sales are outside the installation scope.

Cooling must never depend on the heat sale

If the network stops taking heat, the recovery equipment fails or the connection is under maintenance, the data center carries on as normal. The recovery loop needs its own isolation and control valves and an automatic bypass, and the changeover is tested for real at commissioning. Heat sold is measured with a thermal energy meter, and the billing requirements come from the network owner.

What to send us

Send the process diagram, heat exchanger and recovery equipment data, temperature levels, interface requirements and the installation programme.

Frequently asked questions

Why does data center heat need a heat pump?

Server loop return water is warmer than the exhaust air of an air-cooled hall, but district heating supply needs a higher temperature still. A heat pump lifts it to the network's level, and a higher cooling temperature class means a smaller lift.

What does Finkova deliver for heat recovery?

The valves, pumps and metering around the recovery system, their installation together with the piping and instrumentation, and commissioning support for the interfaces and the bypass.

Discuss the delivery scope

Send the project inputs listed above, or call us to define responsibilities, schedule and next steps.

All contacts

Ville Keltikangas

Data center solutions

Ville Keltikangas

+358 40 704 2514

ville.keltikangas@finkova.fi

More about cookies

Finkova Oy uses Google Analytics (Google) for page views, traffic sources and interaction counts. Google processes usage and device data. Processing may take place outside the EEA. Analytics cookies (_ga and _ga_*) last up to 180 days. Google advertising features are disabled in this implementation.

Your choice is stored in this browser for 180 days (localStorage: finkova-consent-v2). You can change it at any time through Cookie settings in the footer. Withdrawal stops future collection and removes this site’s analytics cookies. The form cookie finkova_form expires at the end of the browser session.

Microsoft Clarity processes interaction and device data to provide heatmaps and session recordings. Its _clck and _clsk cookies connect visits and page views. Microsoft may process data outside the EEA. Advertising storage consent is denied. Cookie details and Microsoft privacy information are linked below.

Finkova privacy notice

Microsoft privacy statement · Clarity cookies

Google privacy policy · Contact Finkova about privacy